รายละเอียดสินค้า เครื่องวัดปริมาณรังสี - Thermo RadEye
All essential functions and software parameters can be easily displayed through the large and clear display window. The display and the alarm-LED can be seen while the instrument is worn in the transparent case. All settings and the data analysis can be done by an optional Windows*-based PC software and a reader device.
-
Operates with with dual phosphor a/b, NaI(Tl) and plastic probes
-
Up to 16 different probe configurations are selectable in submenu
-
Easy to replace probes in-the-field, with simple button-push
-
Weighs 160g (5.6 oz.) with rubber protection, without cable
-
Measures: 110 x 67 x 62mm (4.3 x 2.6 x 2.4 in.)
-
1500 mean and maximum values of count rate or dose rate are recorded internally
-
Versatile operation modes
-
Logs last 250 alarms, error messages and changes of configuration
-
Measured quantities: count rate (cps, cpm), surface contamination (Bq, dps, dpm, Bq/cm2), dose rate (R/h, Sv/h, rem/h)
-
Background subtraction: in count rate and contamination mode
-
Probe library:16 different detectors with corresponding high voltage, calibration factor, dead time correction, overload threshold, detector area and timeout for detector failure
-
Internal memory: The last 1500 measured values are saved and can be read out via PC program; Max and mean value of count rate and dose rate; Time interval is factory preset to 120s by default; Scaler measurements and momentaneous readings stored manually; Logbook with 250 entries for changes of configuration, occurring alarms and errors
-
Averaging filters: Ratemeter filter type - Advanced Digital Filter (ADF), Digital RC-Filter with time constant, 1s to 180s, depending on count rate and count rate change
Ordering Alerts: Accessories Available:
-
Holder with vacuum cup and goose neck # 425522005
-
Transparent case with lanyard # 425067044
-
The RadEye BTcom cover with manual and RadEye.exe update installation file # 425067087
-
Probe cables MHV to MHV and MHV to PET, various lengths available
-
Right-angle-plug converter # KT 162245107
-
Battery lid for inductive chargers # 425067034
-
Desktop holder and inductive charger # 425067083
-
RadEye SX adapter for DP6 probe # 425069360
Compatible with: Thermo Scientific probes DP-6
Compliance: EMC: Disturbance emission - EN 61000-6-3, immunity - EN 61000-6-2
Operation modes:
-
Scaler / Timer with preset countand preset time for sample measurements
-
Continuous ratemeter mode for frisker operation
-
Simultaneous a/b and gross / ROI operation (distinct audible indication for each measuring channel)
Specifications |
Measuring Ranges |
Default: 100,000 cps extendable by individual probe calibration |
Probe cables |
RG 58, MHV connector max. 1.5m (59 in.) |
High Voltage Range |
100 to 1400V with output impedance 2Mohm |
Audible alarm intensity |
80 dB at distance of 30cm (11.8 in.) |
Working temperature |
-20° to +50°C (-4° to 122°F) |
Relative Humidity |
10 to 90 % at 35°C (95°F) not condensing |
Operating Voltage |
1.8 to 4V, battery low voltage starting from 2.3V |
Scaler/Timer |
Preset count, preset time |
Size |
110 x 67 x 62mm (4.3 x 2.6 x 2.4 in.) with rubber protection, without cable |
Weight |
Around 160g (0.35 lb.) including AAA cells and protection sleeve |
Cat. No. |
Description |
4250693 |
RadEye SX Survey Meter |
รีวิว (2)
Customer
10/12/2560 13:51
คุณภาพสินค้าดีมาก
Customer
10/12/2560 13:51
คุณภาพสินค้าดีมาก