Routine laboratory conductivity meter with large multifunctional display, simultaneous display of temperature and automatic temperature compensation. 20 °C or 25 °C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that otherspecial conductivity cells can be connected, including the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell.
Conductivity |
0.0 µS/cm ... 500 mS/cm in 5 measuring ranges or AutoRange additionally for K = 0.1 cm-1: 0.00 µS/cm ... 19.99 µS/cm K = 0.01 cm-1: 0.000 µS/cm ... 1.999 µS/cm |
Temperature | -5.0 ... +105.0 °C |
Salinity | 0.0 ... 70.0 |
TDS | 0 ... 1999 mg/l |
Resistivity | 0.000 ... 1999 MΩcm |
Standard laboratory conductivity meter with large multifunctional display, simultaneous display of temperature and automatic temperature compensation. The data logging capability and the real-time clock allows for all GLP functions. Data output can take place via the optional built-in printer on thermal paper accepted for use for official documents or via the built-in RS 232 digital interface via a PC or external printer.
20 °C or 25 °C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell.
Conductivity |
0.0 µS/cm ... 500 mS/cm in 5 measuring ranges or AutoRange additionally for K = 0.1 cm-1: 0.00 µS/cm ... 19.99 µS/cm K = 0.01 cm-1: 0.000 µS/cm ... 1.999 µS/cm |
Temperature | -5.0 ... +105.0 °C |
Salinity | 0.0 ... 70.0 |
TDS | 0 ... 1999 mg/l |
Resistivity | 0.000 ... 1999 MΩcm |
High-performance laboratory conductivity meter with graphic display and digital recorder function, simultaneous display of temperature, and automatic temperature compensation. A built-in data logger and a real-time clock allows for all QA conforming functions. The optional built-in printer allows data printout on thermal paper accepted for use in official documents. 20 °C or 25 °C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell.
A PC keyboard interface allows an external keyboard or a barcode reader to be connected.
Additional features
Conductivity |
0.0 µS/cm ... 2000 mS/cm in 5 measuring ranges or AutoRange additionally for K = 0.1 cm-1: 0.00 µS/cm ... 20.00 µS/cm K = 0.01 cm-1: 0.000 µS/cm ... 2.000 µS/cm |
Temperature | -5.0 ... +105.0 °C |
Salinity | 0.0 ... 70.0 |
TDS | 0 ... 2000 mg/l |
Resistivity | 0.000 ... 2000 MΩcm |