Mobile
Search:
     Article   Shopping Cart   

   Web Stat
 
Open Web 03/02/2008
Last Update 27/06/2019
All Pageviews
All Products/Service 1110
0105525040475
   Product/Service Categories
Product/Service Price Index
View All Categories (1110)
 Autoclave (Sterilizer)
 Balance
 Bath Water
 Bomb Calorimeter
 Centrifuge
 Colony Counter
 Evaporator Rotary
 Flame Photometer
 Furnace
 Heating Mantle
 Homogenizer
 Hotplate Stirrer
 Incubator
 Microscope
 Mill
 Mixer
 Nutritional Analysis
 Oven
 PH/CON/DO Meter
 Pipettor (Dispenser)
 Pump
 Refractometer
 Refrigeration (Freezer)
 Shaker
 Spectrophotometer
 Stirrer
 Water Purification
 Electrophoresis
 PCR Thermalcycler
 Melting Point
 Viscometer
 Flocculator (Jar Tester)
 Washing Machine
 Ultrasonic Cleaner (Sonicator)
 Gas Generator
 Datalogger
 Freeze Dryer
 Block Heater
 Storage Cabinet
 Safety Cabinet (Laminar Flow)
 Turbidity Meter
 Hydraulic Press
 Thin Section
 Dilutor
 Spiral Plater
 BOD/COD Measure
 Moisture Analyzer
 Environmental Chamber
 Anemometer
 Hygrometer
 Manometer
 Luxmeter
 Sound level meter
 Tachometer
 Glassware
 Radiation Dosimeter (Detector)
 Evaporator Nitrogen
 Nitrogen Protein Distiller
 Block Digester
 Fat Extraction System
 Fiber Extraction System
 Fume Hood
 Test Chamber
 Water Activity
 Microtome
 Microwave Digestion
Atomic Absorption Spectrophotometer
Inductively Coupled Plasma Mass Spectrometer (ICP-
Gas chromatography systems


   Newsletters
Please input email

   Web Links
อาณาจักรของมือสอง
ช้อปปิ้งมอลล์ใหญ่ที่สุดในไทย
ฟรี.!เว็บไซต์สำเร็จรูป
ระบบชำระเงินออนไลน์
ประมูลสินค้าออนไลน์
   Ẻͺ͹Ź
Which one is your favorite product?
Autoclave
Balance
Bath
Centrifuge
Hotplate
Incubator
Oven
Refrigeration
Shaker
Spectro






 
If you are interested in our products . Please contact us by 
www.charanasso.com
Email: sales2charan@gmail.com
Facebook : จรัญเอสโซซิเอทส์

    • Mr. Pharwat ( General manager)     TEL 095-614-1554
    • Mr. Chollophat ( Sale manager ) TEL 087-804-4747
    • Mr. Narumon ( Human resoucer )           TEL 081-628-5060
    • Charanassociate co. ltd (office) TEL 02-1851383-4 , 02-712-5619-20
    • Charanassociate co. ltd (Sale department)TEL 094-478-8647

  ABOUT  THE COMPANY 
  CHARANASSOCIATE  .CO.LTD 
  Whose registered address is at  723/2 Soi Thonglor
  Sukhumvit55  Road, Khongtan -nue ,Wattana, Bangkok 10110 
  Thailand. The company has been  operating since 1982 which is 
  about 34 years from now.  Our main business is the distribution 
  of laboratory equipment, in general for industrial firms and 
  Government sectors i.e  Universities, Colleges, Institute of 
  Technologies and research centers Equipments list include main
  products such as: Autoclave, Balance ,Water bath, Block Heater,
  Bomb Calorimeter, Centrifuge, Flame photometer,  
  Freezer, Furnace, Homogenizer, Heating mantle, Melting point,
  Shaker, Shaking water bath , Utrasoinc bath , Water still etc
Product/Service Detail
Product/Service >> Gas chromatography systems >> Gas Chromatograph - TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS

Gas Chromatograph - TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS - คลิกที่นี่เพื่อดูรูปภาพใหญ่


Gas Chromatograph - TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS








  อีเมล์บอกเพื่อน

Gas Chromatograph - TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS

Code: 001290
Description:

 

TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS

 

Thermo Scientific™  Related applications: Industrial Mass Spectrometry

Take a major step up in productivity and performance with the Thermo Scientific™ TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS. Designed for and developed with high throughput analytical labs, the TSQ 8000 Evo system delivers the highest productivity of our triple quadrupole GC-MS/MS systems, with MS/MS simplicity and even higher performance SRM. This unique system offers deep integration between hardware and software that helps laboratories adapt to their changing environment and deliver quality results on time, every time.
 
Catalog number Product Size Price (USD)
TSQ8000EVO - Request A Quote

Description

Productivity and Performance from EvoCell Technology
  • Triples SRM transition rates without compromising sensitivity in company-run experiments
  • Enables up to three times the sensitivity at the same scan speed in company-run experiments
  • Schedules several thousand unique transitions in a single run while maintaining good sensitivity
  • Has the ability to screen and quantify more than 1,000 compounds in a single run
Accessible Power with Enhanced SRM Software
  • Simplifies automated method development and management and the development of SRM experiments using enhanced AutoSRM software
  • Optimizes SRM scheduling for higher productivity using Timed-SRM software
More Uptime with ExtractaBrite Ion Source
  • High matrix tolerance to minimize sample preparation and cleaning
  • Can be removed for maintenance without breaking vacuum to further enhance uptime
Configured for Ultimate Simplicity, Productivity, and Performance 
The mass spectrometer comes paired with the Thermo Scientific™ TRACE™ 1300 GC or TRACE 1310 GC systems, which offer the unique flexibility of instant connect injector and detector modularity. Add a Thermo Scientific™ AI/AS 1310 autosampler for automated liquid injection or the Thermo Scientific™ TriPlus™ RSH autosampler for additional automated sample handling capabilities to obtain the ultimate in analytical productivity.
 The Thermo Scientific™ TSQ™ 8000 Evo Triple Quadrupole GC-MS/MS is ideal for labs looking for the next step up in triple quadrupole GC-MS/MS productivity. It is the latest evolution of the highly successful TSQ 8000 GC-MS/MS system and the evolution of unstoppable productivity, MS/MS simplicity, and ultimate performance SRM. The TSQ 8000 Evo triple quadrupole GC-MS/MS has been designed with the needs of high throughput analytical laboratories in mind. It is a unique system that offers a harmonious combination of hardware and software features that help laboratories adapt to their changing environment and deliver quality results on time, every time. The mass spectrometer comes paired with the Thermo Scientific™ TRACE™ 1300 GC or TRACE 1310 GC, which offers the unique flexibility of instant connect injector and detector modularity. Add a Thermo Scientific™ AI/AS 1310 auto-sampler for automated liquid injection or the Thermo Scientific™ TriPlus™ RSH autosampler for additional automated sample handling capabilities to obtain the ultimate in analytical productivity. 2 TSQ 8000 Evo Triple Quadrupole Mass Spectrometer Mode (MS) • Electron Impact Ionization (EI), with full scan (FS), SIM, and FS/SIM simultaneous within sample injection, timed acquisition (t-SIM), and FS/t-SIM Modes (MS/MS) • Multiple/Selected Reaction Monitoring (MRM/SRM), timed acquisition (t-SRM), combined SRM/FS, combined t-SRM/ FS, product ion scan, precursor ion scan, neutral loss scan • Ability to convert timed acquisition method (t-SIM/t-SRM) into general mode (segmented) method Ion Source Type • Thermo Scientific™ ExtractaBrite™ Electron Impact Ionization (EI) source (standard) • Chemical Ionization (CI) with Positive Ion Chemical Ionization (PCI) and Negative Ion Chemical Ionization (NCI) source (optional) • Combination EI/PCI/NCI source used without interchange (optional) • Ion source includes ion volume, repeller, source lenses, RF lens and dual filaments in all ionization modes, programmable from 50 °C to 350 °C Source Access • Remove entire ion source or change to CI source in under 2 minutes without venting Software Features • Automated SRM Development (AutoSRM) • SIM Bridge – a tool to import SIM and SRM acquisition tables in commaseparated-values (CSV) formats into AutoSRM and instrument method • Automated acquisition window adjustment based on retention time • Compound based acquisition method setup • Customizable automated tuning Mass Analyzer • Heated, off-axis ion guide for noise reduction and solid, homogeneous, noncoated, maintenance-free quadrupole rods • Fast quadrupole scanning, up to 20,000 u/s Mass Resolution and Mass Stability • Automatic tuning down to 0.4 u and manual tuning below 0.4 u • Selectable SRM resolution settings in method at autotune preset values of 0.7 u, 1.5 u and 2.5 u • Mass Stability better than 0.1 u/ 48 hours/ ∆T ≤ 2 K Collision Energy Range • 0–60 eV Mass Range • 1.2–1100 u Detector • Thermo Scientific™ DynaMax™ XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear range of >107 (0–68 μA) Scanning Capabilities • Up to 20,000 u/s • Ability to acquire more than 97 scans/s in FS when scanning over a range of 125 u • 0.5 ms minimum SRM dwell times • Up to 800 SRM transitions/s Pumping Systems • High-capacity (>300 L/s), dual-stage turbomolecular pump • Mechanical rotary vane 3.3 m3 /h oil pump • Foreline convectron gauge • Optional oil-free scroll pump • Ion gauge (optional) Electron Energy • Adjustable from 0 eV to 150 eV Emission Current • Up to 350 μA Transfer Line Temperature • Up to 400 °C Gas Chromatograph (TRACE 1300 GC or TRACE 1310 GC) Please refer to GC and autosampler specification sheets for additional details • TRACE 1300 GC: Intuitive, single-button start/stop for ease of use with minimal local instrument interaction • TRACE 1310 GC: Complete icon-driven touch screen user interface for direct local instrument control Autosamplers • AI/AS 1310, TriPlus RSH, TriPlus 100 LS, TriPlus 300 HS, and more Instant Connect Modules • User-installable injector or detector assembly can be installed in less than 2 minutes • 0.001–1000 kPa digitally controlled carrier gas with gas saver and septum purge • Split/Splitless (S/SL) injector with optional large volume kit for injections up to 30 μL • Multi-mode Programmed Temperature Vaporization (PTV) injector including on-column capabilities and large volume injection up to 250 μL • Integrated backflush optional for both S/SL and PTV • 1000 kPa digitally controlled carrier gas with gas saver and septum purge • Detector Fast Data Acquisition Rate: up to 300 Hz Oven Temperature • Operating temperature Range: Ambient 3 °C to 450 °C • Operating temperature range with LN2 Cryo: -100 °C to 450 °C • Operating temperature range with CO2 Cryo: -50 °C to 450 °C Oven Performance • Operating range: Ambient +3 °C to 450 °C • Number of ramps/plateaus: 32/33 • Cryogenic Option Minimum Temperature: -100 °C with LN2 ; -50 °C with liquid CO2 • Maximum heating rate: 125 °C/min • Oven cool-down (22 °C ambient): 450 °C to 50 °C in <4 min GC Analytical Performance • Retention Time Repeatability: <0.0008 min • Peak Area Repeatability: <0.5 % RSD • Pressure Set Points Minimum Increments: 0.01 kPa-0.001 psi in all ranges Hydrogen Kit Option • Optional Hydrogen Kit (includes hydrogen sensor and ion volume) required for use with hydrogen carrier gas on the TRACE 1300/1310 GC with the TSQ 8000 Evo MS Instant Connect Helium Saver Module • Compatible when connected to a TRACE 1300 Series GC • Save helium during the analytical run, and when instrument is idle • Analytical conditions remain the same; methods remain intact • Realize significant savings in helium supply throughout the lifetime of your GC or GC-MS instrument Microfluidics Options for TRACE 1300/1310 GC • NoVent for easier column replacement without venting the system • Dual Detector kit for splitting column effluent to two detectors (including MS) • Consists of low-volume, highly inert SilFlow™ technology with finger-tight connectors Direct Sample Probe System Option • Switch to probe in <3 min with GC undisturbed • Available in two styles: rapid heating filament Direct-Exposure Probe (DEP, capable of flash vaporization or pyrolysis at up to 1600 °C) or slower volatilization Direct-Insertion Probe (DIP, capable of accommodating powders and solid samples in a quartz or aluminum crucible) up to 450 °C Product Specifications Data System Software and Options • Thermo Scientific™ TraceFinder™ Software, a common platform for routine GC, GC-MS, LC, and LC-MS quantification • TraceFinder Software for Environmental and Food Safety, with Compound Data Base of over 1300 pesticide SRM transitions • TraceFinder Software for Clinical Research • TraceFinder Software for Forensic Toxicology • Commercial mass spectral library options, including NIST and Wiley libraries; Mass Spectral and GC Data of Drugs, Poisons, Pesticides, Pollutants and their Metabolites (Maurer-Pfleger-Weber library) Performance Specifications GC triple stage mass spectrometers are most frequently applied to trace quantitative analysis in complex matrix. This means that the ability of the system to select against matrix (reduce chemical noise) is a critical performance factor to be taken into consideration. This can be demonstrated with a signal-to-noise ratio (S/N). In addition, a S/N ratio also provides a guarantee against instrument contamination on installation. Finally, low level precision and instrument detection limits (IDL) provide the complete picture. Standard Installation Specifications* (Helium as carrier gas) Electron Ionization SRM • 1 μL of 100 fg/μL octafluoronaphthalene (OFN) will produce the following minimum signal-to-noise for the transition from m/z 272 to m/z 222: 12,000:1 Positive Ion Chemical Ionization SRM • 1 μL of 5 pg/μL benzophenone (BZP) will produce the following minimum signal-tonoise for the transition from m/z 183 to m/z 105: 2,500:1 Reference Specifications† Electron Ionization Full Scan • 1 μL of 1 pg/μL OFN will produce the following minimum signal-to-noise for m/z 272 when scanning from 50–300 u: 1,500:1 Positive Ion Chemical Ionization SRM • 1 μL of 100 fg/μL BZP-D10 will produce the following minimum signal-to-noise for the transition from m/z 193 to m/z 110: 200:1 Negative Ion Chemical Ionization Full Scan • 1 μL of 1 pg/μL OFN will produce the following minimum signal-to-noise for m/z 272: 10,000:1 Negative Ion Chemical Ionization SIM • 1 μL of 100 fg/μL OFN will produce the following minimum signal-to-noise for m/z 272: 4,000:1 Instrument Detection Limit • In EI SRM mode, with helium carrier gas and the AI/AS 1310, TriPlus 100 LS, or TriPlus RSH autosampler (required and configured for liquid injections), eight sequential 2 fg OFN splitless injections monitored for SRM 272→222 produce the following instrument detection limit (IDL), calculated from the chromatographic peak area with 99% confidence interval: IDL ≤ 0.5 fg System Dimensions/Weights Total width of the connected GC-MS system is 80 cm (31 in). System can be operated with back of MS pushed directly against wall or other object. Additional space should be allotted for data system and printer. System Dimensions (height × width × depth) Weight Mass Spectrometer 44 × 40 × 89 cm (17.5 × 16 × 35 in) 61 kg (135 lbs) TRACE 1300 GC 45 × 44 × 60 cm (18 × 17 × 24 in) 35 kg (77 lbs) TRACE 1310 GC 45 × 44 × 67 cm (18 × 17 × 26 in) 35 kg (77 lbs) * Helium standard specifications are performed using a 15 m × 0.25 mm i.d. × 0.25 μm System Qualification Column (SQC). † Reference specifications are typical performance specifications and not confirmed at install
 
Home  |  Product  |  Webboard  |  About Us  |  Article  |  Payment  |  Contact Us  |  Sitemap
© 2001- . TARAD.com. All Rights Reserved.
//