If you are interested in our products . Please contact us by
www.charanasso.com
Email: sales2charan@gmail.com
Facebook : จรัà¸à¹€à¸à¸ªà¹‚ซซิเà¸à¸—ส์
- Mr. Pharwat ( General manager) TEL 095-614-1554
- Mr. Chollophat ( Sale manager ) TEL 087-804-4747
- Mr. Narumon ( Human resoucer ) TEL 081-628-5060
- Charanassociate co. ltd (office) TEL 02-1851383-4 , 02-712-5619-20
- Charanassociate co. ltd (Sale department)TEL 094-478-8647
ABOUT THE COMPANY CHARANASSOCIATE .CO.LTD Whose
registered address is at 723/2 Soi
Thonglor, Sukhumvit55 Road, Khongtan
-nue ,Wattana,
Bangkok 10110 Thailand. The company has been operating since 1982 which is about
34 years from now. Our main business is
the distribution of laboratory equipment, in general for industrial firms and Government sectors i.e Universities, Colleges, Institute of Technologies and research centers Equipments list include main products such as:
Autoclave, Balance ,Water bath, Block Heater, Bomb Calorimeter, Centrifuge,
Flame photometer, Freezer, Furnace,
Homogenizer, Heating mantle, Melting point, Shaker, Shaking water bath , Utrasoinc bath
, Water still etc |
Product/Service >> PH/CON/DO Meter >> Conductivity meter - Bante904P Portable Conductivity/Dissolved Oxygen Meter
| Conductivity meter - Bante904P Portable Conductivity/Dissolved Oxygen Meter Code: 001490 ติดต่ภ02-7125619 Description:

Bante904P Portable Conductivity/Dissolved Oxygen Meter
Multiparameter portable Conductivity/Dissolved Oxygen meter contains 5 measurement modes. The meter is suitable for measuring the Conductivity, TDS, Salinity, Resistivity and DO of the liquids.
Conductivity/TDS/Salinity/Resistivity Mode:
• Multiparameter portable Conductivity/Dissolved Oxygen meter is equipped with a large
backlit LCD display.
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion
factor, seawater and practical salinity measurement modes.
• Linear or pure water compensation improves measurement accuracy of meter.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.

• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 13 parameters, including the number of calibration points,
resolution, stability condition, measurement unit, etc.
• Reset feature automatically resumes all parameters back to factory default settings.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
• Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly.
Model
|
|
Bante904P
|
Conductivity
|
|
|
Range
|
|
0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
|
Accuracy
|
|
±0.5% F.S
|
Calibration Points
|
|
1 to 5 points
|
Calibration Solutions
|
|
10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
|
Temperature Compensation
|
|
0~100°C, 32~212°F, Manual or Automatic
|
Temperature Coefficient
|
|
0.0~10.0%/°C
|
Compensation Modes
|
|
Linear or Pure Water
|
Cell Constant
|
|
K=0.1, 1, 10 or User-defined
|
Normalization Temperature
|
|
20°C or 25°C
|
TDS
|
|
|
Range
|
|
0~100ppt (Max. 200ppt, depending on factor setting)
|
Accuracy
|
|
±1% F.S
|
TDS Factor
|
|
0.1~1.0 (Default 0.5)
|
Salinity
|
|
|
Range
|
|
0~10ppt (Max. 80ppt)
|
Accuracy
|
|
±1% F.S
|
Measurement Modes
|
|
Seawater or Practical Salinity
|
Resistivity
|
|
|
Range
|
|
0~100MΩ
|
Accuracy
|
|
±1% F.S
|
Resolution
|
|
0.01, 0.1, 1
|
Dissolved Oxygen
|
|
|
Range
|
|
0.00~20.00mg/L (or ppm)
|
Accuracy
|
|
±0.2mg/L
|
Resolution
|
|
0.01mg/L
|
Calibration Points
|
|
1 or 2 points
|
Temperature Compensation
|
|
0~50°C, 32~122°F, Automatic
|
Pressure Correction
|
|
60.0~112.5kPa, 450~850mmHg
|
Salinity Correction
|
|
0~50g/L
|
% Saturation of Oxygen
|
|
|
Range
|
|
0.0~200.0%
|
Accuracy
|
|
±2.0%
|
Resolution
|
|
0.1, 1%
|
Temperature
|
|
|
Range
|
|
0~105°C, 32~221°F
|
Accuracy
|
|
±0.5°C, ±0.9°F
|
Resolution
|
|
0.1°C
|
Calibration Points
|
|
1 point
|
Calibration Range
|
|
Measured value ±10°C
|
Others
|
|
|
Hold Function
|
|
Manual or Automatic
|
Stability Conditions
|
|
Low or High
|
Calibration Due
|
|
0 to 31 days
|
Power Off
|
|
Manual or Automatic (10, 20, 30 minutes)
|
Reset Function
|
|
Yes
|
Memory
|
|
Stores up to 500 data sets
|
Output
|
|
USB Communication Interface
|
Connector
|
|
6-pin Mini Plug
|
Power Requirements
|
|
3×1.5V "AA" Batteries
|
Battery Life
|
|
Approximately 150 hours (Turn off the backlit)
|
Dimensions
|
|
170(L)×85(W)×30(H)mm
|
Weight
|
|
300g
|
|
|