Mobile
Search:
     Article   Shopping Cart   

   Web Stat
 
Open Web 03/02/2008
Last Update 27/06/2019
All Pageviews
All Products/Service 1110
0105525040475
   Product/Service Categories
Product/Service Price Index
View All Categories (1110)
 Autoclave (Sterilizer)
 Balance
 Bath Water
 Bomb Calorimeter
 Centrifuge
 Colony Counter
 Evaporator Rotary
 Flame Photometer
 Furnace
 Heating Mantle
 Homogenizer
 Hotplate Stirrer
 Incubator
 Microscope
 Mill
 Mixer
 Nutritional Analysis
 Oven
 PH/CON/DO Meter
 Pipettor (Dispenser)
 Pump
 Refractometer
 Refrigeration (Freezer)
 Shaker
 Spectrophotometer
 Stirrer
 Water Purification
 Electrophoresis
 PCR Thermalcycler
 Melting Point
 Viscometer
 Flocculator (Jar Tester)
 Washing Machine
 Ultrasonic Cleaner (Sonicator)
 Gas Generator
 Datalogger
 Freeze Dryer
 Block Heater
 Storage Cabinet
 Safety Cabinet (Laminar Flow)
 Turbidity Meter
 Hydraulic Press
 Thin Section
 Dilutor
 Spiral Plater
 BOD/COD Measure
 Moisture Analyzer
 Environmental Chamber
 Anemometer
 Hygrometer
 Manometer
 Luxmeter
 Sound level meter
 Tachometer
 Glassware
 Radiation Dosimeter (Detector)
 Evaporator Nitrogen
 Nitrogen Protein Distiller
 Block Digester
 Fat Extraction System
 Fiber Extraction System
 Fume Hood
 Test Chamber
 Water Activity
 Microtome
 Microwave Digestion
Atomic Absorption Spectrophotometer
Inductively Coupled Plasma Mass Spectrometer (ICP-
Gas chromatography systems


   Newsletters
Please input email

   Web Links
อาณาจักรของมือสอง
ช้อปปิ้งมอลล์ใหญ่ที่สุดในไทย
ฟรี.!เว็บไซต์สำเร็จรูป
ระบบชำระเงินออนไลน์
ประมูลสินค้าออนไลน์
   Ẻͺ͹Ź
Which one is your favorite product?
Autoclave
Balance
Bath
Centrifuge
Hotplate
Incubator
Oven
Refrigeration
Shaker
Spectro






 
If you are interested in our products . Please contact us by 
www.charanasso.com
Email: sales2charan@gmail.com
Facebook : จรัญเอสโซซิเอทส์

    • Mr. Pharwat ( General manager)     TEL 095-614-1554
    • Mr. Chollophat ( Sale manager ) TEL 087-804-4747
    • Mr. Narumon ( Human resoucer )           TEL 081-628-5060
    • Charanassociate co. ltd (office) TEL 02-1851383-4 , 02-712-5619-20
    • Charanassociate co. ltd (Sale department)TEL 094-478-8647

  ABOUT  THE COMPANY 
  CHARANASSOCIATE  .CO.LTD 
  Whose registered address is at  723/2 Soi Thonglor
  Sukhumvit55  Road, Khongtan -nue ,Wattana, Bangkok 10110 
  Thailand. The company has been  operating since 1982 which is 
  about 34 years from now.  Our main business is the distribution 
  of laboratory equipment, in general for industrial firms and 
  Government sectors i.e  Universities, Colleges, Institute of 
  Technologies and research centers Equipments list include main
  products such as: Autoclave, Balance ,Water bath, Block Heater,
  Bomb Calorimeter, Centrifuge, Flame photometer,  
  Freezer, Furnace, Homogenizer, Heating mantle, Melting point,
  Shaker, Shaking water bath , Utrasoinc bath , Water still etc
Product/Service Detail
Product/Service >> Melting Point >> Melting Point - SRS

Melting Point - SRS - คลิกที่นี่เพื่อดูรูปภาพใหญ่


Melting Point - SRS








  อีเมล์บอกเพื่อน

Melting Point - SRS

Code: 000878
ติดต่อ 02-7125619
Description:

 


Melting Point Apparatus
MPA160 & MPA161 — Digital melting point system for students

 (DigiMelt vs MelTemp: A Comparison )

 (See what customers said about DigiMelt at BCCE 2010 )

 (Student Tested: see what real students said about using DigiMelt )

 (See a DigiMelt video courtesy of Dr. Ryan Denton, IUPUI Dept. of Chemistry/Chemical Biology)

 (Download a free poster about teaching melting point)

 (Partial list of U.S. schools using DigiMelt)

 (Firmware field upgrade)

 

  • Fast, safe, reliable measurements 
  • Mercury free
  • Built-in digital thermometer
  • Microprocessor controlled ramps
  • Ramp rates from 0.5 to 20 °C/min
  • Easy to clean and maintain
  • Tube tapper packs samples
  • NRTL safety certified 
 

 
 

DigiMelt is a modern, low cost, digital melting point apparatus designed specifically for the student lab. Students learn the visual detection capillary method of melting point determination without the frustration of trying to control the oven temperature. DigiMelt rapidly heats the oven to the programmed start temperature, then ramps at the specified rate. The student carefully observes the samples and records the melting points with a touch of a button.


Digital Temperature Readout

DigiMelt incorporates a platinum resistance temperature detector (RTD) instead of the usual mercury thermometer. This means better accuracy on the readings, and no more mercury cleanup from broken thermometers. The RTD is encased inside the oven block making it virtually unbreakable.

Microprocessor Temperature Control

Some student instruments use a large knob that simply throttles power to the oven without any sense of what the target temperature is. DigiMelt uses an RTD for feedback, so it "knows" the oven temperature. This means the students can enter a start temperature, a ramp rate, and a stop temperature and the microprocessor takes care of the rest. Furthermore, the microprocessor can deliver variable amounts of power to the oven, so it can quickly ramp to the starting temperature, then perform the ramp as slowly as 0.5 ºC/min.

High Quality Optics

Rather than forcing the student to peer through a tiny lens with poor illumination, the DigiMelt uses a large magnifier that allows plenty of eye relief. The user can see all three capillaries easily at a comfortable distance from the instrument. White LEDs are used to provide high-contrast illumination.

Tube Tapper

For many students, the melting point lab is the first time they have touched a capillary. This can lead to lots of capillaries on the floor and many broken capillaries. DigiMelt employs an integral cell phone vibrator motor to let students pack their sample without tapping them on the bench or dropping them through a long glass tube. A molded guide in the chassis allows students to pack three samples at a time.

Easy Maintenance

Cleaning the lens is as simple as removing the lens retaining ring. If a student should break a capillary, the entire lens holder assembly slides out for easy clean up of the broken glass. Replacing thermometers is a thing of the past as the RTD will never break and cannot be removed from the instrument. Unlike conventional incandescent bulbs that must be periodically replaced in some student instruments, the white LEDs used in DigiMelt will last a lifetime.

Safer for Students

The DigiMelt uses an internal RTD thermometer, which means students and TAs are never exposed to toxic mercury vapors. Some student instruments will reach 500 °C and stay at that temperature indefinitely — a severe burn hazard. The DigiMelt’s maximum temperature is 260 °C, which allows testing of virtually all organic compounds a student might examine. Intelligently designed cowling protects students from touching the hot oven. Furthermore, the oven will automatically turn off after being idle for 30 minutes.

 

Safety Concerns in a Melting Point Lab 
 
When using a Mel-Temp When using a DigiMelt ...
Handle your mercury thermometer with care. A broken thermometer leads to a mercury spill.

DigiMelt does not use a mercury thermometer.

Not a concern.

Do not heat the Mel-Temp beyond the upper temperature limit of your thermometer.

DigiMelt can not reach an unsafe temperature.

Not a concern.

Never insert a glass thermometer into a hot Mel-Temp. It may shatter.

DigiMelt uses a solid-state temperature sensor built into the oven.

Not a concern.

Do not leave the Mel-Temp on after your experiment is over. Do not leave the Mel-Temp on unattended.

DigiMelt will turn off when the experiment is over or after 30 minutes of inactivity.

Not a concern.

Do not touch the heating block while it is hot.

DigiMelt's oven is shielded by a safety cowl.

Not a concern.

Do not place your eye on the eyepiece when the unit is hot.

DigiMelt's eyepiece is designed to be viewed from a safe distance. In addition, the safety cowl prevents the user from actually placing their eye against the eyepiece.

Not a concern.

 

 

 

 

 
Specifications
Display
   
Type 4 digit LED
Readout Start, stop or ramp rate, oven temperature, and stored measurement data
   
Temperature
   
Resolution 0.1 °C
Accuracy ±(0.45+0.0045T) where T is temperature in Centigrade
  Typical: ±0.6 °C (<200 °C), ±1.0 °C (≥200 °C)
Reproducibility 0.2 °C
   
Oven
   
Range 50 °C to 260 °C
Ramp rate 0.5, 1.0, 2.0, 5.0, 10, 20 °C per minute
Heat-up time (typ.)    2.5 minutes to 100 °C, 6.5 minutes to 250 °C
Thermometer Built in Pt RTD
Temperature control Closed-loop PID
Safety shut off Automatic after 30 minutes idle
   
Capillaries
   
Dimensions 1.4 mm to 1.8 mm outside dia., 100 mm length
Capacity Up to 3 tubes
Fill height   2 mm to 3 mm
Sample packing Automatic (tube tapper)
   
General
   
Power  
MPA160
100 to 132 VAC, 50 to 60 Hz, 1 A, 75 W nominal
MPA161
200 to 250 VAC, 50 to 60 Hz, 1/2 A, 75 W nominal
Environment 0 °C to 30 °C, non-condensing
Humidity <90%
Weight    2 lbs.
Dimensions 6.5"× 9.5"× 5.25" (WHD)
 